Patient Monitor Edan M50

Jual : Patient Monitor Edan M50



 Harga : Rp. 20.250.000
Specification :

Safety Standards
CE Marking in accordance to Council
Directive 2007/47/EC concerning Medical Devices
IEC 60601-1+A1+A2;IEC 60601-1-2+A1

Physical Specification
Device dimension: 260 mm (L) x 140 mm (W) x 205 mm (H)
Weight: Standard Configuration 3.6 kg

Display
Color TFT LCD 8.4 Touchscreen Optional
Resolution: 800 X 600 dpi
Traces Displayed: up to 8
Waveforms Displayed: up to 11
Various Working Interface Selectable:
Standard Monitoring Display
Large Font Intensive Care Display
Trend Graph/ Monitoring Co-Display
Bed to Bed view Display (Optional)
OxyCRG Dynamic View Display
Drug Dose Calculation Interface
Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s

Operation Environment

Ambient Temperature:
-20 - 55 (-4 -131 F)
Humidity: 15%-95% non-condensing

Power Supply
External Power Supply
100-240V AC, 50/60HZ
Pmax=80VA
Internal Battery Power Supply
Type: Rechargeable Li-ion
Voltage: 14.8 V DC
Capacitance: 2100 mAh (4200 mAh optional)
Battery working period:
up to 6 hours
Recharging time < 150 minutes (2100mAh)
< 360 minutes (4200mAh))

Resp
Method: Trans-thoracic impedance
Operation mode: Auto/ Manual
RR Measurement range:
Adult: 0~120 rPM
Neonate/Pediatric: 0~150 rPM
Resolution: 1rPM
Apnea alarm threshold:
10s,15s,20s (default),25s,30s,35s,40s
Alarm: Yes, audible and visual alarm,
alarm events recallable
Band width: 0.2-2.5Hz (-3dB)
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s


ECG
Lead type: 5-lead and 3-lead selectable
3 leadwire cable: RA; LA; LL or R; L; F
5 leadwire cable: RA; LA; RL; LL; V or R; L; N; F; C
Lead selection: 3-lead: I; II; III; 5-lead: I; II; III; aVR; aVL; aVF; V
Gain selection: x0.125;x0.25; x0.5; x1; x2; x4; auto
Sweep speed: 6.25mm/s,12.5mm/s, 25mm/s, 50mm/s
ECG HR Range:
Adult/Pediatric: 15-300bpm;
Neonate: 15-350bpm
Resolution & accuracy: 1bpm or 1%,
whichever is greater
Filter:
Diagnostic mode: 0.05-150Hz
Monitoring mode: 0.5-40 Hz
Surgical mode: 1-20Hz
Protection: Withstand 5000VAC/50Hz voltage in isolation against
Defibrillation and electrosurgical interference
ST-Segment Detection:
Measurement range: -2.0 mV~2.0mV
Alarm range: -2.0 mV~2.0mV
ST-Segment Arrhythmia analysis and catergorization : Yes
ARR Alarm: Audible and visual alarm, alarm events recallable
Pace maker detection: Yes, and 5 types abnormal status detectable
IEC 60601-2-25; AAMI EC 11/EC 13
IEC 60601-2-27

NIBP
Method: Automatic Oscillometric
Operation modes: Manual/Automatic/Continuous
Auto measurement time interval: Adjustable
1/2/3/4/5/10/15/30/60/90/120/240/480 Minutes
Measurement unit: mmHg/kPa selectable
Measurement types: Systolic, Diastolic, Mean
Pressure range for Adults: Systolic: 40 - 270 mmHg
Diastolic: 10 - 215 mmHg
Mean: 20 - 235 mmHg
Pressure range for Pediatrics: Systolic: 40 - 200 mmHg
Diastolic: 10 - 150 mmHg
Mean: 20-165 mmHg
Pressure range for Neonates: Systolic: 40 - 135 mmHg
Diastolic: 10 - 100 mmHg
Mean: 20 - 110 mmHg
Leak test and pressure auto calibration: Yes
Over-pressure protection: Dual Safety protection
Resolution: 1mmHg
Accuracy: Max mean error 5 mmHg
Max standard deviation 8 mmHg
Alarm: Systolic, Diastolic, Mean
PR from NIBP: Measurement 40~240 bpm
Resolution 1 bpm
Accuracy 3bpm or 3% whichever is greater
Leak test and pressure auto calibration: Yes
IEC 60601-2-30

EDAN SpO2
Measurement & Alarm Range: 0 - 100%
Resolution: 1%; Accuracy: 2% (70-100%, Adult/Pediatric);
3% (70-100%, Neonate)
PR Measurement and Alarm Range: 30 - 300bpm
Resoluton: 1 bpm;
Accuracy: 3bpm
Refresh rate: 2s
ISO 9919

Nellcor SpO2 (optional)
Measurement & Alarm Range: 0 - 100%
Resolution: 1%;
Accuracy: 2-3% (70-100%, Adult/Pediatric);
3-3.5% (70-100%, Neonate)
PR Measurement and Alarm Range: 20 - 300 bpm
Resolution: 1 bpm;
Accuracy: 3bpm (depends on probe)
Refresh Rate: 1s
ISO 9919

Temperature (2 Channels, 1 probe by default)
Measurement /Alarm range: 0~50 (32-122 F)
Probe type: YSI (B Series) and CF-FI
Resolution: 0.1
Accuracy: 0.1 (without probe)
Channel: Dual-channel. Provide T1; T2; T
IEC 12470-4

Quick Temperature (Optional)
Measurement /Alarm range: 25~45
Probe type: Oral/ Axillary / Rectal
Resolution: 0.1
Accuracy: 0.1 (without probe)
Typical measurement time <15s
IEC 12470-4

IBP (2-Channels, optional)
Measuremed Pressure:
ART, PA, CVP, RAP, LAP, ICP, P1,P2
Measurement range:
-50 - 300 mmHg; Resolution: 1 mmHg
Accuracy: 2% or 1 mmHg,
whichever is greater (without probe)
Sensitivity: 5 ?V/V/mmHg;Impedance range:300-3000
IEC 60601-2-34

CO2 (Mainstream and Sidestream, optional)
By Philips Respironics CAPNOSTAT 5 & LoFlo Technology
Range: 0~ 150mmHg
Accuracy: 2% 0 ~ 40mmHg,
5% 41~70mmHg
8% 71~100mmHg
10% 101~150 mmHg
AwRR Accuracy: 1 rpm
Convenient design for intubbated and non-intubated applciations
Possible to work at low sample flow rate: 50ml / minute
Detailed specification refer to the user manual of Respronics
ISO 21647

Recorder (optional)
Built-in, direct thermal pixel array recorder
Up to 3 channels printing
1,2, 3 channels selectable
Print speed: 25mm/s, 50mm/s
Paper width: 50 mm/Record width:48mm

I/O Interface
2-USB Ports
SD Card Socket
RJ-45 Ethernet Port. IEEE 802.3
VGA Output
Analog & Nurse Call output
Defibrillation Synchronization output
WLAN Access Point 802.11g 54Mbps (optional)